BROOKTROUT TECHNOLOGY, INC. TR114-I2M, TR114-I2P, TR114-I4M, TR114-I4P Card Type Telephony Processor NS32FX16/NS32FX164 Processor Speed 25MHz Maximum Onboard Memory 1MB DRAM I/O Options MVIP bus, PEB bus, serial diagnostic ports (2) Data Bus 8/16-bit ISA [Image] CONNECTIONS Function Label Function Label MVIP bus J1 Header to main board J5B Serial diagnostic port J2 Daughterboard header J6A for lines 1-4 PEB bus J3 Header to main board J6B Daughterboard header J5A Serial diagnostic port J8 for lines 5-8 USER CONFIGURABLE SETTINGS Setting Label Position » Interrupt pull-up resistor enabled SW1/1 On Interrupt pull-up resistor disabled SW1/1 Off » PEB bus terminated RP1 Installed PEB bus terminated RP1 Not installed Note:SW1/1 should be on for only one TR112 or TR114 per system. BASE I/O ADDRESS Setting SW1/2 SW1/3 SW1/4 SW1/5 SW1/6 SW1/7 SW1/8 000h On On On On On On On 008h Off On On On On On On 010h On Off On On On On On 018h Off Off On On On On On 020h On On Off On On On On » 260h On On Off Off On On Off 3D8h Off Off On Off Off Off Off 3E0h On On Off Off Off Off Off 3E8h Off On Off Off Off Off Off 3F0h On Off Off Off Off Off Off 3F8h Off Off Off Off Off Off Off Note: A total of 128 base address settings are available. The switches are a binary representation of the decimal memory addresses. SW1/8 is the Most Significant Bit and switch SW1/2 is the Least Significant Bit. The switches have the following decimal values: SW1/8=512, SW1/7=256, SW1/6=128, SW1/5=64, SW1/4=32, SW1/3=16, SW1/2=8. Turn off the switches and add the values of the switches that are off to obtain the correct memory address. (Off=1, On=0) INTERRUPT Setting J4 J7/A J7/B J7/C J7/D J7/E J7/F IR/FONT> Open Open Open Open Open Open Closed IRQ3 Open Closed Open Open Open Open Open IRQ4 Open Open Closed Open Open Open Open » IRQ5 Open Open Open Closed Open Open Open IRQ6 Open Open Open Open Closed Open Open IRQ7 Open Open Open Open Open Closed Open IRQ10 Pins 9 Open Open Open Open Open Open & 10 closed IRQ11 Pins 7 Open Open Open Open Open Open & 8 closed IRQ12 Pins 5 Open Open Open Open Open Open & 6 closed IRQ14 Pins 3 Open Open Open Open Open Open & 4 closed IRQ15 Pins 1 Open Open Open Open Open Open & 2 closed MVIP BUS TERMINATION Setting SW2/1 SW2/2 » Terminated On On Not terminated Off Off DIAGNOSTIC LED(S) LED Color Status Condition LED1 Red On Line 1 is off-hook LED1 Red Off Line 1 is on-hook LED1 Red Blinking Line 1 has been reset LED2 Red On Line 2 is off-hook LED2 Red Off Line 2 is on-hook LED2 Red Blinking Line 2 has been reset LED3 Red On Line 3 is off-hook LED3 Red Off Line 3 is on-hook LED3 Red Blinking Line 3 has been reset LED4 Red On Line 4 is off-hook LED4 Red Off Line 4 is on-hook LED4 Red Blinking Line 4 has been reset MISCELLANEOUS TECHNICAL NOTE The TR-114-I4M and TR-114-I4P models include the daughterboard, while the TR-114-I2M and TR-114-I2P do not.